What's Wrong with this Application? #13

by
Jennifer D'Alessandro
| Mar 10, 2016
This application was sent in by one of our Territory Reps. Can you tell what's wrong with this Ceiling Mounted Work Station Crane?

ceiling mounted work station crane

For the last What's Wrong Post I think we are all in agreement that the application is dangerous and should be tagged and locked out. 

6 comments

Leave a comment
  1. sussan betcher | Feb 27, 2017
    The splice connection on this system is not a Gorbel made/approved splice. It is a homemade connection.
  2. ergolarry | Oct 06, 2016

    missing a hanger

  3. jendal | Apr 15, 2016
    The splice connection on this system is not a Gorbel made/approved splice. It is a homemade connection.
  4. Scott Chelberg | Mar 16, 2016
    Right hand side, top cord of run way looks like they drilled through and put a single hanger. 
  5. Merle | Mar 16, 2016
    no stack section, stop at end of bridge
  6. Steve Weishaar | Mar 11, 2016

    1. I see no safety cables.

    2. I prefer the festoon to be outside the track on a separate cable. But if it is inside there should be a trolley stop prior.

    Not much is visible from the photo.

    Leave a comment